Isolation Step

ID Sequence Number Instruction Expected Position Status Applied At
1 1 Rack out CV-101 breaker at MCC cubicle 7 and lock. OPEN / LOCKED VERIFIED 2026-07-16 06:25
2 2 Switch off and lock the local isolator at the driv... OPEN / LOCKED VERIFIED 2026-07-16 06:30
3 3 Apply belt clamp at head pulley to prevent rollbac... OPEN / LOCKED VERIFIED 2026-07-16 06:35
4 4 Pin the transfer chute gate and confirm no retaine... OPEN / LOCKED EXCEPTION 2026-07-16 06:40
5 1 Disconnect battery isolator and lock. OPEN / LOCKED VERIFIED 2026-07-21 07:16
6 2 Bleed hydraulic accumulator; confirm gauge reads z... OPEN / LOCKED VERIFIED 2026-07-21 07:17
7 3 Lower attachment to ground and fit support stands. OPEN / LOCKED VERIFIED 2026-07-21 07:18
8 1 Rack out CR-101 HV feeder at panel 3 and apply ear... OPEN / EARTHED TEST_RELEASED 2026-07-22 06:20